  1. What is the other options? Do you use any switch between grid and inverter vs breakers? Pink
  2. Good point, check my update on the knife type switch Pink
  3. How much usable average wh per month could i expect from 6600w panels? Could i calculate from your numbers, or your different setup will make it different? Battery limits not counted for now. Expect unlimited capacity for estimate Pink
  4. Maybe i should use this one if back feeding is a issue: If i use 2 in for grid and 1 in for ac out (inverter) then ac out power cut together with grid cut from inverter. Pink
  5. I have plan to use a Dual Power Transfer Switch between my grid line to inverter and direct to house breakers so if any issues with inverter I can easy change grid to go off or direct to house breakers. One think have bother my main: If grid is switch to house breakers and if not ac out on inverter is disconnected first from house breakers then will the inverter be back feed with grid power? I guess that's not wanted. I do have plan for breaker on ac out to.. Pink
  6. Thanks, i guess im a bit low on my 20 x 330 (6600kw) to expect 800kw+ month. I might ad some more kw to my plan. Pink
  7. Thanks for that info, how much panel kw is that? I want to try compare my calculations with real productions numbers. Pink
  8. This is a average month? You have around 10kw panels? Pink
  9. ok i suggested 20cm and my brother in law who will weld and mount this suggested 30cm. How much clearance you have? Pink
  10. What distance between the roof and the panels you recommend? Pink
  11. You have any good alternatives than the typical hybrid inverters as off grid backup? Pink
  12. Crossy, what sofar units you use? i thought they Sofar was ongrid so how you charge and get use of your battery power? Pink
  13. SPF 5000 ES looks like a good solution but its max pv voltage of 450v and i have 2 x 455v so then if SPF 5000 ES i need 3 units not 2 as the others who is 500v limit. Im not set on the Sorotec made units yet.. even Mppsolar is not out yet. Do some ad mppt controllers to improve charge capacity of a all in one setup? Pink
  14. Im happy for all input Crossy. Whats the weak or limited part generally for all in one inverters? What operation / part of unit is good to have extra not used capacity? Pink
  15. The Revo 2 is B9000 more than the Powland i posted before... 17k vs 26k (25k plus 1200 for parallel). Wife translated Muhendis review on Revo2. Seemed to be quite strong both in physical construction and to serve power. If price difference is most for color touch screen im fine without that. I would prefer connection to my pc. Importing is not what it used to be..$200 in delivery for 3x Growatt 5000.
  16. What is the part of the hybrid inverter who most affected if its run near the limit? the charger? Pink
  17. Crossy, i know you mention the GROWATT SPF-5000-ES before, do you use GROWATT and whats the experience? price from china is $630, so if i got 3 of them what i could be the final cost to my door you think? Pink
  18. At 7.30 in the video they mention feed the utility.. possible? Pink
  19. I have sent a mail on the Sorotec REVO III 8000 KW Series (same as MPP max 8000k) who have same as you mention: PV and utility power take the load at same time(can setting) Pink
  20. What i try to ask if it was a hybrid and if it can blend pw power with grid power for home load? I saw on Lazada. I had the impression that hybrid inverters just switched between power sources, but great if the can blend. Pink
  21. Its a good point, but in a way i use to have good experience taking it slow at times too. Now i have looked into Sorotec who is the company who both sell and make inverters like the Easun, but with possibility for parts and service who is ++ GROWATT SPF-3500 and 5000-ES PV and Grid supply power to loads together if PV power is insufficient. its a hybrid right? Pink
  22. I have change my Inverter a few times back and forward: Latterly i decided for Mpp PIP8048MAX for the simplicity, its just perfect for the current setup capacity vice with 500vdc and 4kw pw (2 x 10 panels) input. BUT i dont need to ad much more money then i have 3 x Powland 5.6KW and could example run 3 x 10, or 3 x 9 and 2.5 the charge capacity,, I dont need all that , but the whole system could run more relaxed and it would cover my power fully as long weather is normal.. If any unit fail it must be repaired locally anyway..i guess. still thinking... Pink
  23. Yes thanks,, I found this 3x6mm2 on shopee same seller as the solar wire Pink
×
×