  1. Im happy for all input Crossy. Whats the weak or limited part generally for all in one inverters? What operation / part of unit is good to have extra not used capacity? Pink
  2. The Revo 2 is B9000 more than the Powland i posted before... 17k vs 26k (25k plus 1200 for parallel). Wife translated Muhendis review on Revo2. Seemed to be quite strong both in physical construction and to serve power. If price difference is most for color touch screen im fine without that. I would prefer connection to my pc. Importing is not what it used to be..$200 in delivery for 3x Growatt 5000.
  3. Thanks for the info Bandersnatch Pink
  4. What is the part of the hybrid inverter who most affected if its run near the limit? the charger? Pink
  5. Crossy, i know you mention the GROWATT SPF-5000-ES before, do you use GROWATT and whats the experience? price from china is $630, so if i got 3 of them what i could be the final cost to my door you think? Pink
  6. At 7.30 in the video they mention feed the utility.. possible? Pink
  7. I have sent a mail on the Sorotec REVO III 8000 KW Series (same as MPP max 8000k) who have same as you mention: PV and utility power take the load at same time(can setting) Pink
  8. What i try to ask if it was a hybrid and if it can blend pw power with grid power for home load? I saw on Lazada. I had the impression that hybrid inverters just switched between power sources, but great if the can blend. Pink
  9. Its a good point, but in a way i use to have good experience taking it slow at times too. Now i have looked into Sorotec who is the company who both sell and make inverters like the Easun, but with possibility for parts and service who is ++ GROWATT SPF-3500 and 5000-ES PV and Grid supply power to loads together if PV power is insufficient. its a hybrid right? Pink
  10. I have change my Inverter a few times back and forward: Latterly i decided for Mpp PIP8048MAX for the simplicity, its just perfect for the current setup capacity vice with 500vdc and 4kw pw (2 x 10 panels) input. BUT i dont need to ad much more money then i have 3 x Powland 5.6KW and could example run 3 x 10, or 3 x 9 and 2.5 the charge capacity,, I dont need all that , but the whole system could run more relaxed and it would cover my power fully as long weather is normal.. If any unit fail it must be repaired locally anyway..i guess. still thinking... Pink
  11. Yes thanks,, I found this 3x6mm2 on shopee same seller as the solar wire Pink
  12. Great i will check that in Global then. I was not able to find online but i might search wrong ????. Thanks for great info and help. Pink
  13. Do you mean i should get a combined wire with 3 wires inside? Pink
  14. Thanks for the clarification Crossy. This one ok? My brother in law who is a welding buy and his team mate who is electrician will help me getting this up. From experience its smart to have all i can ready. Btw my brother in law want to get up his own solar too when we got mine working. Do Thailan use: Ground (yellow-green) L→LINE (brown or black) N→Neutral (blue) Pink Pink
  15. 8kw, i looking wires at Lazada and shopee but i see most wire look to be for DC. Same? When i google 8awg i get 10mm2 who is very thick. where you find correct size awg to mm2? If 4mm2 i will have overload with solar cable if it could be used? Pink
  16. What type wire and what wire gauge you used for ac in/out? Pink
  17. What spec of power cable i need for ac inn/out inverter? 8 AWG is maybe way to thick wire? Manual: Suggested cable requirement for AC wires Gauge 8 AWG Pink
  18. 40 meters, on top of garage Pink
  19. I need to order 2 x 100 m solar cable. PV1-F 4 mm ? I found this on shopee. 4mm2 ok? any views on levels of quality/price on solar cables? Pink
  20. Ok maybe i just make a separate ground for the DC surge just outside the wall.. Pink
  21. DC surge ground must goto the same ground i use wit panels? can ac and dc ground be same? could DC surge ground use home ground? Pink
  22. Thanks for useful info om grounding. What type/thickness wire i should use to ground the solar rails and dc surge? Pink
  23. Is there other ground on inverter than the ground port at ac in/out? I expected to connect this ground to the ground in my power panel who is my main ground for home. Pink
  24. Can you explain more? Inverter ac ground i will wire to home ground right? Pink
×
×