  1. Ok thats quite good. I see many talks about cents per day per unit on mining now. What you mine? Do you have some links and details to share? Feel free to share here or PM me with any info you have to share. Pink
  2. Im researching same now... You have some details to share? Pink
  3. Good idea. How much the temperature in your freezer down just before its power back up? Pink
  4. Anyone thought of any usage of the excess solar energy some of us have after batteries are full and its still much energy who could be used for something usefully? Pink
  5. Thanks for that info.. I got same 100% SOC on 3.35 so all is fine then. I also want to be moderate on charge and battery voltage so then all fine. Pink
  6. I have watched quite a few and I think the setup is ok. The question is if its normal or not for the batteries to struggle to get over 3.35v? Capacity wise it seems ok.. Pink
  7. I see some of my batteries not easy to charge over 3.35 or so I guess the new settings on 3.30 as starting level was better but maybe 3.35 will be better from what i see from my batteries. Pink
  8. One more day with charging. My growatt and JK BMS show batteries full just before lunchtime. This 2 days i wake up to around 50-60 A left battery capacity. It seems that some batteries not easy to get over 3.35v but im not sure if thats even needed? After some balancing it look like 3.3x v per cell. 277 amp. 99% capacity is the standard i can expect. When balancing over3.3 look like its 80% done by de-charge who is higher and very less added to lowest batteries. So 55.x will end up with 53.x when finish balancing. Pink
  9. Today fist full day with all set up as it should be to work normally. Total generated today is 24 kvh. Its funny how carefully Im with the usage of electric now when its "free" Pink
  10. Now i understand why active balancing only at the end of the charge is discussed. I had set my JK BMS to start balance from dc 3.45v as in this video but ended up with deviation of dc 0.2xx v who took much time to get balanced back and I feel it messed up the charge process and I also guess its ineffective. Now i have change my settings and try balance from dc 3.3v tomorrow. Lets hope thats a better and smoother way of charge. Pink
  11. So i have adjusted the charge voltage some up. Actual charge voltage is some lower than what in the settings on the inverter. Currently charge at 50A or so now who is much better. Pink
  12. I must admit Im curious to see if if will produce around what i expected and calculated it to do. Things seems to run a bit low for now.. I get less than 10A charge currently Pink
  13. So i was sure to wake up early today to get some charge before grid was taken down ( will be down whole day) So i started up charge from solar as soon there was some sign of daylights but that was very optimistic from a solar beginner. I had to wait an hour or some before see and sign on charge from the solar. Now grid is down and i have got up my wifi monitoring on the master inverter. I have not figured out yet if it show data from master only or master and slave inverter together. Pink
  14. Yes, It also a plus to have planed and build it so it can be managed and fixed as much as possible by myself. Pink
  15. All was up and running at lunchtime but because of the weather and my batteries needed to be charged I turned off AC Out on the inverters. I only tested 15 minutes or so today offline from grid. Pink
  16. I was seduced many times when planing and buying with some cheaper options but I tried to choose good value (Good quality at good price) With the hope that It will last for many years but time will show. I tried to plan the setup to have some extra margins for the capacity on for example inverter. But time will show.. I spent more or less exact 300k for all. Electric bill lately been around B 4k (+/- 500) so maybe 6-7 years needed for ROI. Pink
  17. I got the news early this morning. Then i decided To get this finish and up as soon as possible, so I skipped breakfast and started right away.???? Pink
  18. Im currently charge at around 20Amp per battery from the "sun" Pink
  19. I dont really have sun today and tomorrow they told grid will be down 10-12 hour or so from early morning so I just grab what i can get now to charge up my batteries for tomorrow so i have to use grid for home today. Very happy to see it working..next i will get up the monitoring software on wifi so i got some more feeling on whats going on. Pink
  20. Just got all up and running with the 2 growatts in parallel, so right now im on solar power !!! Pink
  21. JK BMS default does not charge or take load so it had to be setup. the i got the expected voltage. pink
×
×