A good clean and a gas check should be order of the day.
-
There is no flat 4 Baht / kWh rate, you will be on the tariff 2.1.2. Anyway, a Schneider 3-phase board, dependent upon the number of breaker positions, is going to run to 5-10k for the board, 150 for each single-phase MCB and 3-4k for your 100A incoming MCCB. Your sparks should be able to size the board for what you need and future expansion.
-
-
Indeed, if she's new and "undamaged", this lady was a granny!
- 259 replies
-
- 24
-
Yeah, that was my understanding too.
- 259 replies
-
- 23
-
It's not been 4 Baht per unit for a good while unless you are a very low user. https://www.pea.co.th/en/electricity-tariffs Note that the numbers on the above link do not include the FT (fuel tariff) which is currently 0.3972 Baht/kWh I did pick the wrong tariff for the calculator but even with the correct tariff you're looking at about 11,300 Baht per month and that's only going to go up.
-
I think you are under-estimating your energy cost here. The S21-200TH is rated at 3010W, let's say 3kW for easy sums. 3 x 24 x 30days = 2,160kWh per miner/month. Feeding that number into the PEA bill-estimator here https://eservice.pea.co.th/estimatebill/# gives an overall cost of 15,300Baht per miner/month. Is it still viable at that level? How about mining other coins? By the way. Powering one miner with solar would need 70 x 340W (about 140m2) panels plus associated inverters and battery packs.
-
Is this the one famous over here..
Crossy replied to Martin71's topic in UK & Europe Topics and Events
Running here: - -
You size the breaker to protect the cable (2.5mm2) and to handle the potential start-up surge from a conventional A/C. Modern inverter units don't have the surge but it never hurts to be future-proof in case your unit isn't big enough. We wired all our A/C locations in 4mm2 (on 20A breakers) "just in case" the additional cost was small.
-
OK that's the right sort of box for 3-phase. Personally, I wouldn't lose the existing single-phase supply, if it has a 15/45 meter that's an additional 45A! Unless you are going to add a lot to the domestic side of things, I'd just replace the Eaton box with something like the baby Schneider and have done with it. it may also be advantageous to have your mining rig separately metered from the house. Do you have a link to the spec. for your server rack, it's unclear what power supply it needs from the photos. Again, do you have a sparks you can use (the PEA chaps could be available for some moonlighting).
-
OK, so you have two supplies and two meters. I'd leave the existing alone. Your 50A 3-phase incomer is good for about 8-10 miners spread across the 3-phases, so until you reach that level, I'd keep it as it is. Do you have a pet sparky who can do your wiring? There's a lot of energy and potential death in a 3-phase supply!
-
The main regulations book you need is "รหัสมาตรฐาน EE 2001-56 มาตรฐานการติดตั้งทางไฟฟ้าสำหรับประเทศไทย พ.ศ. 2556" (Standard EE 2001-56 Electrical Installation Standard for Thailand, 2013). There are associated standards for lightning protection and the like which you probably won't need. Get it here or good bookstores for 225 Baht https://eitstandard.com/มาตรฐานการติดตั้งทางไฟ-2/# As far as I'm aware it is not available in English. Unfortunately, there's not a Thai equivalent of BS7671 or AS3000 which would make life easy. The best we can do is the information published by PEA which is linked in one of the pinned threads. If you want to wire to an English language standard you could do worse than to follow AS3000 (Aussie standard) which would meet or exceed any Thai requirements.
-
OK THW 2.5mm2 on 20A breakers will do the trick for your outlet circuits, run a green or green yellow 2.5mm2 for ground. Run 1.5mm2 on 10A breakers for lighting. I'd leave the 63A until it "fails" inspection, if the inspector is friendly, it could be "lubricated" into compliance For your pump you need NYY. Run 2 core if you put in a ground rod at the pump.