  1. The best site or place to search is in the Sois behind Caddie Shack Soi 17. Called Suksabai Villa. Prices have crept up, but nice houses built there now and eventually the mess that was Eden will become a condo or houses.
  2. Initally what happened is my aquaponics fish filter blew back and I ingested a mouth full of fish poop. Took antibiotics for 2 weeks and Miracid for 2 weeks as stomach burning. So 1 month later and still not settled down.
  3. I watched the guy wiring the control box and he was using a screwdriver way to big for the terminal screws and breaking the insulation round the screws, then when one wire combination didn't work he changed to another until the pump worked. So more fool me for not paying attention to the final setup and taking a pic.
  4. Yes, my wife keeps reminding me. ????
  5. Doesn't it show the supply on 4? Thanks for your patience. I've come up with another drawing. Is this correct?
  6. Wrong. Think this is how it's connected. Motor between 4 and 6. Checking.
  7. Thanks. The guys that drilled the bore connected up the pump box. I didn't really look at the wiring when I removed it to reconnect my new Intelligent pump control box. (Something my wifey reminds me of). So the motor winding should be between 4 and 5 if it's in series with the capacitor? I think the wiring diagram shows L is black and N blue.
  8. peterfranks you still never posted some pictures. ????
  9. Thanks. I am closer to Kuchinari hospital so I'll just go in there tomorrow morning.
  10. Picture of the origional FROG pump controller wiring.
  11. My stomach has been painful for about 1 month. Bloating, irregular bowel movements, wind and general discomfort. I thought I should go and let the Dr have a look in there with a camera. I live in the Kalasin area. Can someone recommend a place to go for the test? Preferably not a private hospital. Thanks.
  12. I couldn't take the photo of the origional FROG pump control box circuit as it's hissing down rain and the pump control box is now right on top of the bore The only circuit I have is on the side of the pump control box. The FROG book that came with the pump does not have a wiring diagram The pump does not work with the origional FROG control box reinstalled. This was the sequence of events. 1. The FROG pump was installed in the 60m bore hole. 2. The FROG controller box connected and pump operated. 3. Changed controller to Intelligent Pump controller and pump didn't work. 4. Reinstalled origional FROG controller and pump didn't work. 5. Thought it was possible I could have broken the pump control cable (pushing and pulling) so I cut out the cable length from the top of the bore to the Intelligent Pump about 6m. Reinstalled the FROG control to the cable at the top of the bore casing, pump still not working.
  13. These pictures are of the Intelligent Pump controller wiring instructions. Sorry I can't get it any clearer. Seems to me the capacitor is across Line and Neutral. The capacitor is between neutral and common, then a link from common to Line.
  14. Ok will take more photos. There's no vibration of the water pipes, so I presume the pump isn"t running.
  15. I didn't actually measure 220v across the windings, was just sayjng that I can't see how I could blow the motor up. Even puttkng 220v across the winding shouldn't blow it up. I think.
  16. I can't see how I could have blown up the motor as 220V anyway is still 220V across the motor winding. How could I have blown up the motor? Or, what combination of wires would blown up the motor? I did try a few combinations when the Intelligent Controller didn't work. ????
  17. Trip reset pressed and nothing tripped.
  18. I did reinstall the origional Fox controller after the Intelligent Controller didn't work, but the pump didn't work. I connected the wiring to the Intelligent Pump as it showed on the circuit diagram. Pump didn't work.
  19. I have a FROG 0.5 HP submersible pump. It had a 3 wire connected control box and all worked OK. Control box wiring picture included. I installed an Intelligent Pump control box with different control wiring diagram. Picture included. I wired the pump as per the Intelligent Pump wiring diagram and the pump doesn't work. Should the pump work in this Intelligent Pump wiring configuration? I reconnected the pump with the old control box, right at the point the cable goes down the bore, and the pump doesn't work. So I've either dislodged the pump power cable or blown up the pump. I've replaced the capacitor. Any ideas? The first picture is the FROG box connection. The second pic. is the Intelligent Pump connection. I'm also not sure of my electrical theory: if the capacitor is wired in parellel with the motor, at start up XC will be very low so overall parallel cct. Z will be low so maximum current to start the motor. If the capacitor is wired in series with the motor I leads E at start up so max. current to motor. Is a start capacitor wired in series or parellel with the motor?
  20. That also was a horrible accident. I went and looked at all the burnt out cars etc they removed from that accident. They had them parked on the side of a road (can't remember which road). What a mess.
  21. That was a horrible day. But the worst part is they just rebuilt the burnt out shell. How can that building be safe? Every time this comes up there is never an answer to who was prosecuted over this? Every thing goes quiet. People have tried to investigate those responsible but then ...quiet. When I book into a hotel I check out the fire escape right to the outside as some have access to the lower level but locked going the outside. One trip to Banggers and the outside fire escape door was locked, and the receptkon said "if you don't like it stay somewhere else". This was a long time ago, maybe things have changed.
×
×