How about a solar car port on a budget?
lom replied to Crossy's topic in Alternative/Renewable Energy Forum
I tell ya, the guy is a living power plant.. -
How about a solar car port on a budget?
lom replied to Crossy's topic in Alternative/Renewable Energy Forum
I compared his April numbers to mine and I had 1500KWh from solar and 55KWh from PEA. My panels output are half of his ie 14.4KWp and my batteries are fullly charged just after midday. I don't know what to do with the sunshine in the afternoon, guess I have to get an EV soon..😃 -
How about a solar car port on a budget?
lom replied to Crossy's topic in Alternative/Renewable Energy Forum
That a lot of unused energy, imagine if you could use all of that all of the day.. Are you planning to open an EV charging station for the neighborhood? 😉 -
Two houses, same lot - one solar system
lom replied to unheard's topic in Alternative/Renewable Energy Forum
Yes but what if the houses are connected to different phases on the grid? It doesn't matter if they are, both of the houses has their own ATS which means that a house is either connected to the joint inverter or to its own grid. -
Two houses, same lot - one solar system
lom replied to unheard's topic in Alternative/Renewable Energy Forum
Yes and if you want to keep the grid connection with the old meter then you can install an Automatic Transfer Switch at the old house. You can also choose to have the old meter removed and only feed the old house from the underground cable from your solar inverter. My inverter is supplying power to our main house and to the two smaller rental cabins that we have. -
British Fighter's Promising Career Ends in Tragic Overdose in Thailand
lom replied to snoop1130's topic in Pattaya News
An echo from the past... -
That's what many Canadians has done, I've never seen so many of them before as I've done this year.
-
How about a solar car port on a budget?
lom replied to Crossy's topic in Alternative/Renewable Energy Forum
That is true if you believe that 150 units is only 150 baht... -
Unveiled: Secret Drug Removed from Scene of Shane Warne’s Thailand Death
lom replied to webfact's topic in Koh Samui News
A story from a sensationalistic newspaper like the Daily Mail isn't worth the paper it is printed on. Can be true or can be invented, the latter being more likely. -
Request for CT advice/Information
lom replied to 007 RED's topic in Alternative/Renewable Energy Forum
I would probably replace the 6x415 panels with 6x550 to get more power for the day when PEA switches your meter to a digital one. I would then install a small battery to cover the nightly consumption but not until you get a digital meter. 4 of the old panels can be used for the washroom. -
Some parts are way overpriced.. Deye 10KW 1-phase 75000 + VAT = 80250 can be had from shopee for 69000 Combiner box 15900 ouch ! A PV only combiner box is 2500-3000 and the AC breaker and surge protector is no more than 500 baht. Still, they should not mix high voltage DC and AC in the same box! Batteries 165000 + VAT 11500, you can get 2x15KW LVTopSun from Shopee for 122000 baht. Same physical dimension but only 2 battery packs. Permit? You only need a permit to change the house structure if you mount the panels on your roof and you get that from the tessaban/amphoer. Doesn't cost 15900 + VAT.. You also need to tell PEA that you are installing solar but you don't need their permit to do it. They may come and inspect your install but it is without cost for you.
-
Bangkok Police Nab Chinese Fugitive Linked to B11 Billion Fraud
lom replied to webfact's topic in Bangkok News
It is quite the opposite, no way Thai authorities would oppose an extradition when requested by China. -
It is the simplest way to know how much excess energy you have which then can be diverted, their eddi for controlled making of hot water works in the same way. Home Assistant knows how much excess energy you have but there is no way to communicate that to zappi or eddi that I know of.
-
It is a Deye and I did previously have grid charging enabled for Time 1 but that was when we had lots of grid cuts. That to make sure that I started midnight with not less than 28% SOC which would take me through the night without power cuts. The screenshot is from the Solarman remote monitoring and configuration program.
-
Yes. Continue a bit further down is section 5.7 to "Time of use". Time of use when activated controls charging/discharging when grid power is present. The setting takes precedence over the battery setting in section 5.6. I have the battery setting in 5.6 at 10% deepest discharge but at 20% between 4 am to 8 am in time of use. If battery goes down to 20% when grid is active then grid will take over, if grid is inactive then I have another 10% until the inverter stops producing from battery. You can also charge the battery from the grid at a certain time based on the SOC setting in Time of use.
-
It is possible, the EPS output from a Deye inverter can supply your whole house if you want, not only the essential consumers. It can supply up to the limit of the inverter (in your case 10KW) from PV and/or battery and if you don't have enough power from PV and or battery then it will take the missing part from the grid through Deye's grid connector (grid-assist). You will not even need a CT if you run everything on the EPS output, there is a setting for it: "Zero Export To Load: Hybrid inverter will only provide power to the backup load connected. The hybrid inverter will neither provide power to the home load nor sell power to grid. The built-in CT will detect power flowing back to the grid and will reduce the power of the inverter only to supply the local load and charge the battery."
-
It is correct that you will need a CT to protect from export into the grid through the AVR which most likely won't like power flowing through it in opposite direction to which it normally operates. Most inverters do have a UPS/EPS output for emergency light and equipment and that is the only active output from battery and PV when grid is not present. The inverters grid connection follows the frequency and voltage of the grid and will become inactive (island mode) when grid isn't present. What brand of inverter did Thai Solar System quote to you? In general I'd say by looking at the picture that this is a very "el cheapo" Thai system. A PV combiner box combines 2 or more strings and contains fuses, breakers, and over voltage protection, that is the upper part of the box in your picture. I would never mix DC (PV or Batt) and AC (grid) in the same box! If the installer has to put everything in one box in order to keep the price down or his profit up then I would go somewhere else. Using lead-acid batteries is also a sign of made in Thailand for Thais..