Does my CU set up comply with Thai regulation?
Crossy replied to jim234's topic in The Electrical Forum
The customs chaps at the airport are on the lookout for easy pickings. Over limit on booze or tobacco, there's no mechanism for paying duty so it's customs party time! -
Does my CU set up comply with Thai regulation?
Crossy replied to jim234's topic in The Electrical Forum
You will likely get a 15/45 3-phase which is 45A per phase (usual incomer 50A - increase to 63A when the inspector has gone). Have you done a prospective load estimate? Most of us manage on a single-phase 15/45 ???? Depending upon where you are you might be able to get a 30/100 single-phase supply, use a 100A incoming breaker ???? EDIT I must do that drawing I promised, sorry it's been chaos at work. -
A post which breaches the AseanNow Community Standards has been removed. Let's stick to condolences people!!
-
RIP Kwasaki ???? Definitely an excellent member and contributor. Both times I came off in my biking days and idiot car driver was involved, any indication what happened??
-
Growatt SPF5000ES Offgrid 9kw DIY Solar Project
Crossy replied to Pink7's topic in Alternative/Renewable Energy Forum
-
Growatt SPF5000ES Offgrid 9kw DIY Solar Project
Crossy replied to Pink7's topic in Alternative/Renewable Energy Forum
Looks OK, verify with the inverter manual. Note that normal terminology is that a switch or breaker is Closed = On, Open = Off. -
Does my CU set up comply with Thai regulation?
Crossy replied to jim234's topic in The Electrical Forum
Let me do a sketch once I get home, I don't have Visio on my office machine. If you do it like the inspector is expecting then he will be happy. The inspections usually are pretty minimal, if he sees what he expects to see. Ours was 30 minutes max, 25 minutes of which was him drinking coffee and gassing with Madam. He looked at the rod, and the MEN routing, noted our RCDs and moaned that the poles weren't straight. -
Does my CU set up comply with Thai regulation?
Crossy replied to jim234's topic in The Electrical Forum
If your 4-pole incomer has a dedicated N way then no real reason not to use it. You could even make the N-E link after the breaker which would allow complete isolation from the outside world. Not sure how the inspector would react to that mind. The diagrams in the PEA doc are single-phase of course where you DO switch both L and N lines. Have a read of this page https://www.electrolesk.com/Work/Wiring of Three Phase Distribution Board.htm You need to do something like this with the added N-E MEN routing: - -
My annual "are you still alive" check by my pension provider uses an App on the phone (you can do a paper one if you want). Get a selfie on the screen and blink slowly. App goes beep and you're done.
-
I've always found these apps to work best on a smartphone. I've really no idea why, possibly they simply have better cameras. And, I invariably have to get someone else to actually hold the phone, my brain just can't cope with holding ID and phone, getting everything in the picture and then pressing the shutter.
-
Leaving with a child born in Thailand
Crossy replied to Hiane's topic in Thai Visas, Residency, and Work Permits
This ^^^. Also, if travelling alone with the youngster you should carry a letter from the other parent permitting you to do so. -
Drain pipes for kitchen? Blue pipes? Clean water only?
Crossy replied to OneMoreFarang's topic in DIY Forum
-
Does my CU set up comply with Thai regulation?
Crossy replied to jim234's topic in The Electrical Forum
Making everything 2-pole (or 1P+N) is going to confuse the heck out of the inspector (not to mention your sparking contractor). A diagram may help but if you get a mean inspector ... Personally, I'd stick to the standard Thai kit, single pole MCBs and multiple small ground bars for each RCD. -
Does my CU set up comply with Thai regulation?
Crossy replied to jim234's topic in The Electrical Forum
This PEA document explains the minimum requirements, the OP seems to meet it. Groundwire Mk2 book-Manual.pdf BUT as @bluejetssuggests a diagram would be most useful. Switching the N on a 3-phase supply is not usually recommended, you need a specific 4-pole breaker which connects N first and disconnects it last. Just use a 3-pole, it's easier and cheaper. The important diagram, my translation. -
You can also get an adaptor to use with those "Picnic Gas" canisters which are available everywhere. https://www.lazada.co.th/products/1-i4305958682-s17131457226.html
-
Yes. I got this from our local Mom-n-Pop hardware outlet. EDIT https://www.lazada.co.th/products/buga-i4771784017-s19897436300.html
-
The C-curve only affects the magnetic switch-on surge protection, in reality no hazard. The Type-AC RCBO section can be "blinded" by pulsating DC faults, since pretty well everything these days has switching power supplies these days you should really avoid Type-AC (although better than nothing) use Type-A if at all possible.
-
Prevention of swimmer's ear (external ear infection)?
Crossy replied to Lorry's topic in Health and Medicine
Related quote from Mock the Week - "I thought PPI was what you got from swimming without goggles" Fetching my coat! -
DIY 28kw/h Storage : EVE LF280k x 32 LiFePO4 Batteries
Crossy replied to Pink7's topic in Alternative/Renewable Energy Forum
Check, check and check again before actually connecting the BMS. You don't want to let out the Magic-Smoke! The result of not RTFM! No, not mine!!